Dolby 3D Calibration ProcedureFor Doremi Digital Cinema ServersVersion 1.4The information contained herein is confidential and may not
5 DefinitionsThe following terms are key definitions for performing the Dolby3D calibration process.Luminance: The measured value of brightness; refl
6 Document Revision HistoryDate Version Description09/02/2008 1.0 First version.11/17/2008 1.1 Server requirements revised.02/04/2009 1.2 Section 2.2
Table of Contents1 INTRODUCTION...
1 Introduction1.1 PurposeWhen installing a Dolby 3D system, the installer needs to perform a calibration procedure. This calibration procedure invol
2 Preliminary Phase2.1 Server RequirementsOnly a server with proper firmware and software versions can support the Dolby 3D system. To support this
3 Dolby 3D ConfigurationThe server must establish communication with the DFC100 from Dolby to enable the Dolby 3D system. This DFC100 must, therefore
6. Back in the main Device Manager window, select the Dolby DFC100 device:Figure 3: Device Manager GUI – “Dolby DFC100” Device Selected7. Set the IP a
4 CalibrationYou need to install the packages provided by Doremi for the calibration. Follow the steps below:1. Plug in the USB stick containing the
4.2 Wizard - Second Step The second wizard window is illustrated below:Figure 5: Wizard Window - Second Step1. Open the CineLister application.2. In
4.3 Wizard - Third StepFigure 6: Wizard Window - Third Step1. Make sure to stop the last clip played.2. Load and play the clip “FS Peak White 3D” aga